Prehospital Emergency Care · 2005 · 41 citations · 12 references
Health ProfessionsEmergency Medical ServicesEmergency MedicineAssistive TechnologyPrehospital Emergency CareResuscitationBreathing SupportCardiopulmonary ResuscitationMechanical VentilationCompressionCompression Performance EvaluationPrehospital VentilationQuality Of Chest CompressionsRepeated Measures AnalysisRepeated Measures AnovaResuscitation Quality ImprovementResuscitation Quality Metrics
UNLABELLED: Numerous studies have documented poor cardiopulmonary resuscitation (CPR) performance among prehospital providers during both simulated and actual resuscitations. Previous studies have shown that a real-time, voice assist manikin (VAM) system may improve CPR performance. OBJECTIVE: To determine whether VAM prompting would improve CPR performance by prehospital providers during simulated resuscitation. METHODS: In this prospective, randomized, crossover design, 114 prehospital providers performed two 3-minute sessions of one-rescuer CPR on a VAM-resuscitation manikin: one round with the VAM feature turned on and one with the feature turned off. The primary outcomes were measured at 15-second intervals and included the fraction of correct compressions, the mean compression depth, the fraction of correct ventilations, and the mean ventilation tidal volume. Generalized estimating equations were used to analyze the repeated measures. RESULTS: The VAM prompting was not directly associated with correct compressions during one-rescuer CPR in a cohort of subjects naïve to the system. However, the general decay in correct compressions seen over 3 minutes was attenuated with VAM prompting. Neither the compression depth nor the decay in compression depth over time was affected by VAM prompting. In contrast, VAM prompting did affect the fraction of correct ventilations and attenuated the time-dependent decline in correct ventilations in tidal volume. CONCLUSIONS: Use of VAM did not directly improve compression or ventilation rate or quality in this cohort of prehospital providers. However, use of VAM did prevent decay of compression and ventilation performance over time.
12
Decay in Quality of Closed-Chest Compressions Over Time
David Hightower, Stephen H. Thomas, Charles K. Stone et al. · Annals of Emergency Medicine · 1995 · 317 citations
Medicine, Physiology, Surgery +10
The effect of rescuer fatigue on the quality of chest compressions
F.Javier Ochoa, Enrique Ramalle Gómara, V Lisa et al. · Resuscitation · 1998 · 279 citations
Health Professions, Physical Medicine, Respiratory Therapy +9