Physical review. A, General physics · 1981 · 36 citations · 36 references
Natural SciencesChemistryPhysicsInorganic ChemistryRadiation DetectionRadiation MeasurementMetal OxidesX-ray DetectionX-ray DetectorsX-ray SpectroscopyDetectorsMuon DetectionMuon Detectors
Muonic x-ray spectra from 57 oxides have been measured with Ge detectors at the muon channel of SIN. Coulomb capture ratios and muonic x-ray intensities were deduced. A novel method was applied for oxides of heavier elements. The results exhibit for the first time systematic relations between capture ratios, the x-ray intensities in the oxidized element and in the oxygen, and the radius of the atoms. Periodic behavior with $Z$ was established in many cases.
36
The Capture of Negative Mesotrons in Matter
Enrico Fermi, Edward Teller · Physical Review · 1947 · 1K citations
Natural Sciences, Chemistry, Physics +11
On coulomb capture ratios of negative mesons in chemical compounds
H. Schneuwly, V.I. Pokrovsky · Nuclear Physics A · 1978 · 109 citations
Natural Sciences, Chemistry, Physics +10
Study of X-rays and nuclear γ-rays in muonic thallium
H. Backe, R. Engfer, U. Jahnke et al. · Nuclear Physics A · 1972 · 84 citations