EngineeringElectrical EngineeringPhysicsElectromagnetismFinite Element AnalysisFinite Element MethodsMagnetic Circuit AnalysisNonlinear Circuit AnalysisNonlinear Finite Element AnalysisMagnetic Circuit DesignMagnetic FluxMagnetic Flux DensityMagnetic ModelingNonlinear Magnetic Circuit ModelingSystematic Error AnalysisSystematic Error CorrectionSystematic Error Mitigation
The watt balance is operated in two asynchronous measurement modes to obtain the voltage–velocity ratio U/v and the force–current ratio mg/I, respectively. The magnetic flux density will change between the two modes when the effect due to the coil current is taken into account, particularly for watt balances using a soft magnetic material in the magnetic circuit. Normally, the linear component of the magnetic flux density change can be easily eliminated by reversing the coil current; however, the quadratic component remains as a systematic error, i.e. a non-linear error. In this paper, we use a theoretical analysis and a differential finite element method to investigate the behaviour of the quadratic dependence in a typical magnetic circuit. Several strategies are discussed to minimize this error in the magnetic system design for the watt balance.