Assessing sedation in the pediatric intensive care unit by using BIS and the COMFORT scale
82
Citations
20
References
2002
Year
BIS measurements evaluated in clinically relevant ranges compare favorably with a standard assessment of the level of sedation. However, comparisons of BIS and COMFORT scale measurements at isolated moments during a prolonged pediatric intensive care unit course of sedation were less correlated. BIS may be best used to identify and prevent oversedation of patients in the pediatric intensive care unit.