IEEE Transactions on Nuclear Science · 2013 · 27 citations · 31 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyDetector TechnologyMedical ImagingPositron Emission TomographyRadiation Imaging DetectorsScintillation DetectorsCoincidence DetectionDetector Spatial ResolutionDetector Timing ResolutionDetectorsReadoutScintillator CrystalsTime PickoffTiming Resolution
Clinical TOF PET systems achieve detection efficiency using thick crystals, typically of thickness 2-3 cm. The resulting dispersion in interaction depths degrades spatial resolution for increasing radial positions due to parallax error. Furthermore, interaction depth dispersion results in time pickoff dispersion and thus in degraded timing resolution, and is therefore of added concern in TOF scanners. Using fast signal digitization, we characterize the timing performance, pulse shape and light output of LaBr <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> :Ce, CeBr <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> and LYSO. Coincidence timing resolution is shown to degrade by ~50 ps/cm for scintillator pixels of constant cross section and increasing length. By controlling irradiation depth in a scintillator pixel, we show that DOI-dependence of time pickoff is a significant factor in the loss of timing performance in thick detectors. Using the correlated DOI-dependence of time pickoff and charge collection, we apply a charge-based correction to the time pickoff, obtaining improved coincidence timing resolution of <; 200 ps for a uniform 4 × 4 × 30 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> LaBr <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> pixel. In order to obtain both DOI identification and improved timing resolution, we design a two layer LaBr <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> [5%Ce]/LaBr <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> [30%Ce] detector of total size 4 × 4 × 30 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> , exploiting the dependence of scintillator rise time on [Ce] in LaBr <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> :Ce . Using signal rise time to determine interaction layer, excellent interaction layer discrimination is achieved, while maintaining coincidence timing resolution of <; 250 ps and energy resolution <; 7% using a R4998 PMT. Excellent layer separation and timing performance is measured with several other commercially-available TOF photodetectors, demonstrating the practicality of this design. These results indicate the feasibility of rise time discrimination as a technique for measuring event DOI while maintaining sensitivity, timing and energy performance, in a well-known detector architecture.
31
High-energy-resolution scintillator: Ce3+ activated LaBr3
Edgar van Loef, P. Dorenbos, C.W.E. van Eijk et al. · Applied Physics Letters · 2001 · 655 citations
Benefit of Time-of-Flight in PET: Experimental and Clinical Results
Joel S. Karp, Suleman Surti, Margaret E. Daube-Witherspoon et al. · Journal of Nuclear Medicine · 2008 · 584 citations · Full text