Publication | Closed Access
Mechanically braked Wingate powers: agreement between SRM, corrected and conventional methods of measurement
28
Citations
26
References
2004
Year
Single TestEngineeringKinesiologyHealth SciencesMechanicsConventional MethodsMechanical EngineeringSrm ValuesApplied PhysiologyRehabilitationBraked Wingate PowersStructural MechanicsS PowerPhysical Medicine
In this study, we assessed the agreement between the powers recorded during a 30 s upper-body Wingate test using three different methods. Fifty-six men completed a single test on a Monark 814E mechanically braked ergometer fitted with a Schoberer Rad Messtechnik (SRM) powermeter. A commercial software package (Wingate test kit version 2.21, Cranlea, UK) was used to calculate conventional and corrected (with accelerative forces) values of power based on a resistive load (5% body mass) and flywheel velocity. The SRM calculated powers based on torque (measured at the crank arm) and crank rate. Values for peak 1 and 5 s power and mean 30 s power were measured. No significant differences (P >0.05) were found between the three methods for 30 s power values. However, the corrected values for peak 1 and 5 s power were 36 and 23% higher (P <0.05) respectively than those for the conventional method, and 27 and 16% higher (P <0.05) respectively than those for the SRM method. The conventional and SRM values for peak 1 and 5 s power were similar (P >0.05). Power values recorded using each method were influenced by sample time (P <0.05). Our results suggest that these three measures of power are similar when sampled over 30 s, but discrepancies occur when the sample time is reduced to either 1 or 5 s.