Annals of Neurology · 2009 · 150 citations · 26 references
MedicineNeurologyNeuroscienceDiagnostic ImagingElectrophysiologyEpilepsyBrain ImagingElectrode PlacementElectroencephalographyElectroencephalography In EpilepsyEpilepsy SurgeryNeuroimaging In EpilepsyElectrode Placement AccuracyElectroencephalographic LocalizationElectroencephalographic Source ImagingMagnetic Source LocalizationMagnetoencephalographyNeural Source LocalizationNeuroimaging In Seizure EvaluationSeizure Mapping
OBJECTIVE: Intracranial electroencephalography (ICEEG) with chronically implanted electrodes is a costly invasive diagnostic procedure that remains necessary for a large proportion of patients who undergo evaluation for epilepsy surgery. This study was designed to evaluate whether magnetic source imaging (MSI), a noninvasive test based on magnetoencephalography source localization, can supplement ICEEG by affecting electrode placement to improve sampling of the seizure onset zone(s). METHODS: Of 298 consecutive epilepsy surgery candidates (between 2001 and 2006), 160 patients were prospectively enrolled by insufficient localization from seizure monitoring and magnetic resonance imaging results. Before presenting MSI results, decisions were made whether to proceed with ICEEG, and if so, where to place electrodes such that the hypothetical seizure-onset zone would be sampled. MSI results were then provided with allowance of changes to the original plan. RESULTS: MSI indicated additional electrode coverage in 18 of 77 (23%) ICEEG cases. In 39% (95% confidence interval, 16.4-61.4), seizure-onset ICEEG patterns involved the additional electrodes indicated by MSI. Sixty-two patients underwent surgical resection based on ICEEG recording of seizures. Highly localized MSI was significantly associated with seizure-free outcome (mean, 3.4 years; minimum, >1 year) for the entire surgical population (n = 62). INTERPRETATION: MSI spike localization increases the chance that the seizure-onset zone is sampled when patients undergo ICEEG for presurgical epilepsy evaluations. The clinical impact of this effect, improving diagnostic yield of ICEEG, should be considered in surgery candidates who do not have satisfactory indication of epilepsy localization from seizure semiology, electroencephalogram, and magnetic resonance imaging.
26
A Randomized, Controlled Trial of Surgery for Temporal-Lobe Epilepsy
Samuel Wiebe, Warren T. Blume, John P. Girvin et al. · New England Journal of Medicine · 2001 · 3.5K citations · Full text
Outcome with respect to epileptic seizures.
Jerome Engel · Medical Entomology and Zoology · 1993 · 2K citations
Medicine, Neurology, Neurosurgery +11
Surgical treatment of the epilepsies
Stephen M. Bloomfield, Andrew G. Shetter · Surgical Neurology · 1988 · 1.2K citations
Orrin Devinsky, S. Pacia · PubMed · 1993 · 1.2K citations
Intracranial EEG Substrates of Scalp EEG Interictal Spikes
James X. Tao, Amit Ray, Susan Hawes‐Ebersole et al. · Epilepsia · 2005 · 415 citations · Full text