Permeation rate measurements by electrical analysis of calcium corrosion

Ralph Päetzold, A. Winnacker, Debora Henseler, Valentina Cesari, Karsten Heuser

Review of Scientific Instruments · 2003 · 236 citations · 8 references

Concepts

Abstract

Highly sensitive permeation measurements are crucial for the characterization and development of polymeric substrates for flexible display applications. In particular, organic light-emitting devices require substrates with extremely low permeation rates for water and oxygen. Here we demonstrate a concept for measuring ultralow permeation rates. The amount of oxidative degradation in a thin Ca sensor is monitored by in situ resistance measurements. The benefits of this technique are demonstrated for polyester foils with single- and double-sided barrier coatings. A sensitivity limit is imposed by the quality of the encapsulation. The resulting base line contribution to the water vapor transmission rate of a glass reference is below 10−6 g/m2 day at accelerated test conditions.

References

8