Radiation Research · 1959 · 23 citations · 6 references
Natural SciencesNuclear EngineeringNuclear MedicineNuclear PhysicsRadiation DosimetryRadiation MeasurementAbsorbed DoseCalorimetryExternal Beam DosimetryGamma-ray DetectorsGamma-ray InstrumentationRadiation Dose MeasurementCalorimetric DetectorsDose Conversion FactorDosimetry FundamentalsEnergy Absorption CoefficientHigh-energy Photon Beam DosimetryIon Pair ProductionIonization
The power in the gamma -ray beam from a Cs137 teletherapy unit has been measured with a calorimeter. Comparison with ionization measurements gives a conversion factor of 2959 plus or minus 44 ergs/cm2r, and combining this result with the calculated absorption coefficient gives a value for W of 33.9 plus or minus 0.5 ev/ion pair.
6
The Albedo of Various Materials for 1-Mev Photons
Evans Hayward, J.H. Hubbell · Physical Review · 1954 · 83 citations
Absolute Measurement of W air for Sulfur-35 Beta Rays
Z. Bay, W.B. Mann, H. H. Seliger et al. · Radiation Research · 1957 · 31 citations