Publications of the Astronomical Society of the Pacific · 2005 · 597 citations · 8 references
Natural SciencesAstronomyInfrared AstronomyObservational AstronomyStellar AstronomyCalibrationInfrared InstrumentationInfrared PhotometryInfrared TelescopesNear-infrared AstronomyStellar PhotometryAbsolute CalibrationAbsolute PhotometryAstronomical Instrument CalibrationCalibration Of Infrared InstrumentsGround-based ObservationsGround-based PhotometryPhotometrySpace-based Observations
IRAC is absolutely calibrated by comparing photometry of A stars near the north ecliptic pole to ground‑based predictions and a stellar atmosphere model, with corrections for array position and centroid within the peak pixel. The calibration achieves 3 % accuracy, with photometry stable to 1.5 % rms over a year and 1 % dispersion on intermediate timescales, though one secondary calibrator shows 5 % variability consistent with a Cepheid.
The Infrared Array Camera (IRAC) on the Spitzer Space Telescope is absolutely calibrated by comparing photometry on a set of A stars near the north ecliptic pole to predictions based on ground-based observations and a stellar atmosphere model. The brightness of point sources is calibrated to an accuracy of 3%, relative to models for A star stellar atmospheres, for observations performed and analyzed in the same manner as the calibration stars. This includes corrections for location of the star in the array and the location if the centroid within the peak pixel. Long-term stability of the IRAC photometry was measured by monitoring the brightness of A dwarfs and K giants (near the north ecliptic pole) observed several times per month; the photometry is stable to 1.5% (rms) over a year. Intermediate-time-scale stability of the IRAC photometry was measured by monitoring at least one secondary calibrator (near the ecliptic plane) every 12 hr while IRAC is in nominal operations; the intermediate-term photometry is stable with a 1% dispersion (rms). One of the secondary calibrators was found to have significantly time-variable (5%) mid-infrared emission, with period (7.4 days) matching the optical light curve; it is possibly a Cepheid variable.
8
The Infrared Array Camera (IRAC) for the <i>Spitzer Space Telescope</i>
G. G. Fazio, Joseph L. Hora, M. L. N. Ashby et al. · The Astrophysical Journal Supplement Series · 2004 · 3.4K citations · Full text
Natural Sciences, Astronomy, Physics +17
The <i>Spitzer Space Telescope</i> Mission
The Astrophysical Journal Supplement Series · 2004 · 2.9K citations · Full text
Natural Sciences, Astronomy, Physics +17