Spine · 2006 · 169 citations · 21 references
MedicineOrthopedic SurgerySurgeryOrthopedicsRadiographic AnatomySpine SurgeryAtlantoaxial InjurySpinal TraumaVertebral AnatomyVertebral Artery SurgeryAnatomic Risk AssessmentAtlantoaxial FixationPreoperative Imaging EvaluationSurgical Approaches To The Vertebral ArterySurgical Technique ComparisonThree-dimensional TomographyTomographyTransarticular Fixation
In Brief Study Design. We evaluated the trajectories of atlantoaxial transarticular and C2-pedicle screws in 3 dimensions using computerized tomography. Objective. To compare the anatomic risk for vertebral artery injury associated with C2-pedicle and atlantoaxial transarticular screws. Summary of Background Data. The atlantoaxial fixation technique using C1-lateral mass screws combined with C2-pedicle screws is considered a safer technique for preventing vertebral artery injury than atlantoaxial transarticular fixation. However, few reports have compared the anatomic risk of vertebral artery injury associated with C2-pedicle screws with that of transarticular screws. Methods. A total of 62 consecutive patients with cervical lesions were evaluated using 3-dimensional images reconstructed by a computer-assisted navigation system. We compared the maximum possible diameters of the atlantoaxial transarticular screw and C2-pedicle screw trajectories, and examined whether the maximum possible diameters were limited by the height or width of the bony structure in screw trajectories ≤4 mm in diameter. Results. Mean maximum possible diameters did not differ significantly between the trajectories of 124 atlantoaxial transarticular and 124 C2-pedicle screws. In screw trajectories ≤4 mm in diameter, 57.1% of transarticular screw trajectories were limited by the height of the bony structure, and all pedicle screw trajectories were limited by the width. Conclusions. C2-pedicle screw placement has nearly the same anatomic risk of vertebral artery injury as transarticular screw placement. Preoperative 3-dimensional evaluation may be useful for choosing the best surgical technique. Three-dimensional computerized tomography was used to compare the screw trajectories of atlantoaxial transarticular and C2-pedicle screw placement. C2-pedicle screw placement had nearly the same risk for vertebral artery injury as transarticular screw placement. Preoperative 3-dimensional evaluation may assist in choosing the best surgical technique.
21
Posterior C1–C2 Fusion With Polyaxial Screw and Rod Fixation
J. Harms, Robert P. Melcher · Spine · 2001 · 1.5K citations
Fractures and dislocations of the cervical spine
W. E. Gallie · The American Journal of Surgery · 1939 · 719 citations