Endoscopic Electrocoagulation in Upper Gastrointestinal Hemorrhage

J Papp

JAMA · 1974 · 33 citations · 4 references

Concepts

Abstract

Emergent upper gastrointestinal endoscopy was performed in seven actively bleeding patients. The site of bleeding was found. Electrocoagulation with a flexible suction coagulator electrode (Cameron-Miller) passed through an endoscope (Olympus GIF) resulted in cessation of bleeding in all cases. The lesions coagulated were as follows: four benign gastric ulcers, one duodenal ulcer, one area of hemorrhagic gastritis, and one gastric varix. No morbidity or death occurred as a result of the electrocoagulation. The patient with a gastric varix died due to esophageal variceal bleeding. The remaining six patients were treated medically. No longer is endoscopy only a diagnostic technique; it can also be therapeutic. This new technique may be a valuable addition to the approach of treatment of upper gastrointestinal hemorrhage. (<i>JAMA</i>230:1172-1173, 1974)

References

4