Anesthesia & Analgesia · 1997 · 11 citations · 9 references
MedicineOtolaryngologySurgeryLaryngologyPulmonologyTemporomandibular Joint SurgeryAirway AssessmentAirway ObstructionEndotracheal IntubationLaryngeal ReconstructionTracheal ReconstructionAirway InspectionBronchoscopyBronchoscopy-guided Airway ManagementCapnographyEndotracheal Tube Position AssessmentFiberoptic Bronchoscopy-guided IntubationIn-transit CapnographyTube Position Verification
Direct visualization is one of the most reliable means of ensuring correct placement of an endotracheal tube [1]. Fiberoptic bronchoscopy usually affords a clear view of the vocal cords and other airway structures; however, many factors can obscure visualization. We describe a new method of capnometry through the suction connector of a fiberoptic bronchoscope (FOB) to confirm tube position during a visually impaired fiberoptic endotracheal intubation. Case Report A 46-yr-old man with ankylosing spondylitis presented for total reconstruction and implantation of bilateral temporomandibular joints. He was edentulous, with a 15-mm maximal mouth opening. He could not flex, extend, or rotate his neck. His trachea was midline. The patient was premedicated with glycopyrrolate, 0.3 mg intravenously. Topical lidocaine to the oropharynx with superior laryngeal nerve and transtracheal blocks achieved excellent anesthesia of the airway. After nasal dilation, a FOB (LF-2; Olympus, Lake Success, NY) was advanced via the right naris. When secretions obscured visualization through the FOB, attempts to wipe the FOB clean and restore visualization were made but failed. At this point, the male Luer-Lok connector of the gas sampling line (Safe & Sure; Datex, Helsinki, Finland) from a spectrometer (Capnomac Ultima; Datex, Helsinki, Finland) was attached to the suction connector of the FOB, and the suction valve lever was depressed (Figure 1). A continuous capnograph was detected over six breaths, which indicated that the FOB was in the trachea. An endotracheal tube (ETT) was advanced over the FOB while fiberscopic capnography was continued. Correct ETT placement was confirmed by conventional capnography.Figure 1: Illustration of the suction and biopsy port orientation of the Olympus LF-2 fiberoptic bronchoscope (Lake Success, NY) and the fiberscope nomenclature. To use capnography through the fiberoptic scope, the Luer-Lok end of the gas sampling line from a gas analyzer is attached to the suction connector (inset). The suction valve lever is then depressed to provide a continuous measurement of end-tidal CO (2). Figure courtesyof Olympus America, Inc.Later, we successfully used capnography through a FOB to verify its tracheal placement in the next eight consecutive patients who required awake fiberoptic intubation. In one patient, thick secretions made fiberoptic visualization of the airway difficult, but the FOB was advanced into what appeared to be the trachea. Capnography through the FOB produced an irregular ETCO2 waveform that disappeared after two cycles of spontaneous ventilation (Figure 2 [top]). This was considered consistent with a sampling port obstructed by the esophagus. Had the FOB reached the stomach, a reduced level of CO2[2] and no variation with spontaneous ventilation would have been expected. Therefore, the FOB was withdrawn and repositioned into the trachea, which produced ETCO2 waveforms consistent with tracheal FOB placement (Figure 2 [bottom]).Figure 2: Top, Capnograph waveform (arrow) obtained with the inadvertent placement of the fiberscope tip into the esophagus. The end-tidal CO2 diminishes and then disappears. Bottom, After repositioning the fiberoptic bronchoscope into the trachea, end-tidal CO2 waveforms (arrow) characteristic of those seen with tracheal placement and adequate ventilation are seen.Discussion Various methods of assessing ETT position have been described [1,3-6]. Direct visualization of the vocal cords as the ETT is advanced into the trachea is considered to be the standard criterion for proper tube placement. When the trachea is intubated, characteristic ETCO2 waveforms are seen, which are distinct from the irregular, rapidly diminishing ETCO2 wave-forms observed with esophageal intubation and ventilation of the stomach [1]. A normal capnogram, however, can be obtained during spontaneous ventilation if the sampling tip is located in the pharynx [7]. With the FOB well advanced, the FOB tip would have to be turned sharply back on itself, which would require some force to accomplish. The FOB did not have to be forced during insertion in the cases presented herein. Several factors may compromise visualization of airway structures during fiberoptic intubations, including blood, secretions, anatomic abnormalities, patient movement, or laryngoscopist inexperience. When visualization is not possible, however, measurement of ETCO2 is one of the most reliable determinants of tube position. Capnography through a FOB helps to determine whether the FOB is within the trachea before the ETT is advanced. This saves time and prevents an undiagnosed esophageal intubation. It may also reduce the potential for trauma and bleeding associated with advancement of the ETT, which can compromise further attempts to fiberoptically visualize the airway. Aspiration of secretions and blood through the suction channel may cause FOB capnometry to fail and contamination of the suction channel to occur. However, we experienced no failures of FOB capnography despite two cases in which visualization was obscured. Possible contamination of the FOB suction channel is addressed by following the manufacturer's recommended device cleaning and sterilization protocol. Capnography through the FOB requires an unobstructed suction port and channel. We recommend that patency of the suction lumen be confirmed before its use for capnography. Insufflating oxygen through the suction lumen (valve opened) for 1 s achieves this. When done properly, the oxygen stream is palpable at the distal FOB tip. Once the gas sampling line is attached to the suction connector, the suction valve must be opened to allow the capnometer to aspirate gas for analysis and display. FOB capnometry must be interrupted if suction or oxygen insufflation through the suction channel is desired. Capnography with fiberoptic bronchoscopy has been used to assess the effects of lobectomy on regional lung function [8], to monitor high-frequency jet ventilation [9], and to evaluate hypoventilation in sedated pediatric patients during fiberoptic bronchoscopy [10]. This is the first report in which capnography has been used to assist and confirm correct ETT placement during awake fiberoptic intubation. We consider the probability of endotracheal positioning to be great when the FOB has been generously and smoothly advanced and the capnograph pattern is regular. If there is no pattern, or when the pattern is irregular, an esophageal placement is possible. In our experience, capnography with fiberoptic bronchoscopy is a reliable method of confirming ETT position when fiberoptic visualization is obscured.
9
Patrick K. Birmingham, Frederick W. Cheney, Richard J. Ward · Anesthesia & Analgesia · 1986 · 314 citations
Transtracheal illumination for optimal tracheal tube placement
S. Mehta · Anaesthesia · 1989 · 35 citations
Medicine, Anesthesiology, Surgery +11