Plastic & Reconstructive Surgery · 1996 · 10 citations · 11 references
Life SciencesImmunologyAllergyHypersensitivityImplant SurgeryAllergic ConditionsDrug AllergyImplant-associated InflammationSkin-implant Interface
In the literature, multiple conditions, including hematomas, self-limited cutaneous eruptions, and generalized systemic complaints, have been attributed to breast implants. We report the first case of idiosyncratic allergic reaction to the textured surface of a mammary prosthesis. The reaction was documented by patch testing of the textured surface compared with smooth-surface silicone controls. Symptoms resolved with removal of the implants and have not recurred after insertion of smooth-walled implants. Whereas the physiology of this condition remains unclear at this time, it is important to recognize the possibility of a delayed hypersensitivity reaction when considering reconstruction with a textured breast implant.