Observation of an Isokinetic Temperature and Compensation Effect for High-Temperature Crude Oil Fouling

Christopher A. Bennett, Richard Stanley Kistler, Krish Nangia, Walid Al-Ghawas, Nadia Al-Hajji, Ahmad Al-Jemaz

Heat Transfer Engineering · 2009 · 54 citations · 17 references

Concepts

Abstract

The initial fouling rates of four crude oils were determined at a nominal bulk temperature of 315°C, an initial heated wall shear stress of 13 Pa, and initial surface temperatures between 375 and 445°C. These initial fouling rates ranged from 1.3(10− 6) to 7.8(10− 5) m2 K/kJ. Corresponding Arrhenius plots were linear with the initial fouling rates passing through an isokinetic temperature of 407.5°C. A plot of the natural logarithm of the pre-exponential factors [7.6(104)–5.2(1015) m2 K/kJ] versus the apparent activation energies (128–269 kJ/mol) was also linear, confirming the validity of the isokinetic temperature and the presence of the compensation effect. Below the isokinetic temperature, the relative fouling rates were Crude Oil C > Crude Oil A > Crude Oil D > Crude Oil B; above the isokinetic temperature, the relative fouling rates were reversed (Crude Oil B > Crude Oil D > Crude Oil A > Crude Oil C). Chemical characterization of a fouling deposit suggested that the dominant fouling mechanism at these conditions was coking, with significant contributions from sedimentation (iron sulfide) and corrosion (∼ 340 μ m/yr) of the 304 stainless steel test material.

References

17