IEEE Transactions on Industry Applications · 1984 · 57 citations · 0 references
EngineeringElectrical EngineeringElectric MachinesPower ElectronicsElectric MotorsInduction MachinesMachine WindingsMotor Starting MethodsThree-phase CircuitsThree-phase MachinesPrimary Resistance StartingReduced Voltage StartingResistorsSquirrel Cage Motor StartingSquirrel-cage Induction MotorsThree-phase Induction MachinesThree-phase Induction MotorsThree-phase Motors
The most commonly used methods of reduced-voltage starting of three-phase ac squirrel-cage motors are reviewed. They include primary reactor, primary resistors, autotransformer, part winding, wye-delta, and solid state. Other methods are used but less often.