Journal of Neuroscience · 2014 · 54 citations · 12 references
Magnetoencephalography has long held the promise of providing a noninvasive tool for localizing epileptic seizures in humans because of its high spatial resolution compared with the scalp EEG. Yet, this promise has been elusive, not because of a lack of sensitivity or spatial resolution but because the large size and immobility of present cryogenic (superconducting) technology prevent long-term telemetry required to capture these very infrequent epileptiform events. To circumvent this limitation, we used Micro-Electro-Mechanical Systems technology to construct a noncryogenic (room temperature) microfabricated atomic magnetometer ("magnetrode") based on laser spectroscopy of rubidium vapor and similar in size and flexibility to scalp EEG electrodes. We tested the magnetrode by measuring the magnetic signature of epileptiform discharges in a rat model of epilepsy. We were able to measure neuronal currents of single epileptic discharges and more subtle spontaneous brain activity with a high signal-to-noise ratio approaching that of present superconducting sensors. These measurements are a promising step toward the goal of high-resolution noninvasive telemetry of epileptic events in humans with seizure disorders.
12
Dmitry Budker, Michael Romalis · Nature Physics · 2007 · 1.8K citations · Full text
Subfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
D. Sheng, Nezih Dural, Michael Romalis · Physical Review Letters · 2013 · 343 citations · Full text
Magnetoencephalography with a chip-scale atomic magnetometer
Tilmann Sander, Jan Preusser, Rahul Mhaskar et al. · Biomedical Optics Express · 2012 · 294 citations · Full text