Magazine of Concrete Research · 1949 · 10 citations · 0 references
EngineeringCivil EngineeringMaterials ScienceBuilding MaterialsStructural EngineeringStructural MaterialsConcrete ConstructionConcrete MaterialsConcrete TechnologyPrestressed ConcreteStructural ConnectionsAnchorage LengthPrestressed Concrete BehaviorPrestressed Concrete StructuresStress Transfer Length
Summary: Research into the properties and problems of prestressed concrete has been pursued for some ten years in the Civil Engineering Laboratories of Leeds University and this paper deals with the results of tests on prestressed concrete columns to find the transmission lengths required to ensure complete bond between the wires and the concrete. It is seen that the initial transmission length for 0·2 inch diameter wires stressed to 70 tons per sq. in. is about 125 diameters (25 in.) and for 0·08 inch diameter wires stressed to 100 tons per sq. in. about 60 diameter (5 in.). These values apply only if the concrete is of good quality. It is seen that bad placing can cause these transmission lengtlrs to be greatly increased. A transmission length of approximately 400 diameters was measured in badly placed concrete. It is recommended that som~ form of mechanical locking device should be used when structures of short length are to be prestressed by 0·2 in. diameter wires. The use of 0·08 in. wires eliminates any uncertainity with regard to the end anchorage.