Transactions of the ASAE · 2001 · 13 citations · 0 references
EngineeringBuilding ScienceEnvironmental EngineeringAir PollutionTransport PhenomenaVentilationAir Pollution DispersionAir Pollution ModelingAir QualityAirflow DistributionAirflow SimulationAtmospheric DispersionAirborne Pollutant TransportContaminant DispersionContaminant Dispersion ModelingContaminant Transport ModellingFreestall HousingPollutant Dispersion ModelingSlope AngleWind Tunnel Modeling
Onethirtieth scale models of naturally ventilated freestall dairy houses were tested in a wind tunnel toinvestigate the relationship between roof type (openridge, semimonitor, monoslope), roof slope angle (16.7, 18.4), andwind direction and air movement inside and outside the house. Dispersion properties of gaseous contaminants from the housewere predicted from these air movement results. A proposed parameter, PU , was developed with respect to airflow momentumand airflow vectors showing that the openridge house had characteristics to easily transfer contaminants from inside tooutside and to increase dispersion at the leeward side. It was predicted that the monoslope type might decrease contaminanttransport and create a high concentration area near the leeward side of the building. When the open side of the semimonitortype ridge faced windward, contaminants dispersed more readily than when the ridge faced leeward. In addition, a smalldifference in slope angle made a large difference in air movement and contaminant diffusion of openridge houses.