Materials SciencePulse AnnealingEngineeringCrystalline DefectsMechanical EngineeringApplied PhysicsMaterials CharacterizationStress AnnealingCopper FilmsStressstrain AnalysisChemical Vapor DepositionVacuum DeviceThin FilmsChemical DepositionMechanical StressMechanics Of MaterialsMicrostructureThin Film Processing
An apparatus has been built for the measurement of mechanical stress in vacuum deposited films. A study of the stress changes during pulse annealing has been made with copper films deposited at several substrate temperatures between -150°C and +75°C. The annealing spectrum shows a prominent peak centred near room temperature which matches a resistance annealing peak in similar films and also in cold worked copper. The fall of tensile stress in this region suggests a vacancy mechanism. The theory of Murbach and Wilman for the behaviour of initial stress with temperature is not supported by these results.