Stress Annealing in Vacuum Deposited Copper Films

48

Citations

17

References

1957

Year

Abstract

An apparatus has been built for the measurement of mechanical stress in vacuum deposited films. A study of the stress changes during pulse annealing has been made with copper films deposited at several substrate temperatures between -150°C and +75°C. The annealing spectrum shows a prominent peak centred near room temperature which matches a resistance annealing peak in similar films and also in cold worked copper. The fall of tensile stress in this region suggests a vacancy mechanism. The theory of Murbach and Wilman for the behaviour of initial stress with temperature is not supported by these results.