Concepedia

Publication | Closed Access

Use of intraosseous blood to assess blood chemistries and hemoglobin during cardiopulmonary resuscitation with drug infusions

74

Citations

22

References

1999

Year

Abstract

Intraosseous and central venous blood biochemical and hemoglobin values were similar during hemodynamic stability and throughout 30 mins of resuscitation if no drugs were given through the intraosseous site. However, differences existed after 30 mins of CPR and infusions through the intraosseous site. Laboratory values may be erroneous when intraosseous blood is used during periods of resuscitation of >5 mins if drugs and fluid boluses have also been infused through the site. For reliable values, an intraosseous site for sampling only may be reasonable.