Total respiratory compliance in infants and young children with congenital heart disease

Charlotte Davies, S G Cooper, M. E. Fletcher, D. J. Hatch, P Helms, I. Gordon

Pediatric Pulmonology · 1990 · 26 citations · 23 references

Concepts

Abstract

The multiple occlusion technique was used to measure total respiratory system compliance (Crs) in 62 infants and young children with congenital heart disease (age range, 2 days to 2 years). Measurements were found to be reproducible in nine infants in whom repeat measurements were possible (maximum deviation between measurements less than 10%). The incidence of failure to obtain accurate results was no greater than when studying infants without cardiopulmonary disease. However, in the presence of severe growth retardation or alinearity of volume-pressure data, results may be difficult to interpret in individuals. Results of Crs were related to non-invasive assessments of cardiac disease severity using chest radiography and echocardiography. After the effects of growth had been taken into account, a significant negative relationship was found between Crs and the right pulmonary artery to aortic ratio, which reflects pulmonary vascular engorgement (P = 0.003, R2 = -0.40). However, no significant relationship was found between Crs and chest X-ray score (P = 0.27).

References

23