27th Joint Propulsion Conference · 1991 · 27 citations · 1 references
EngineeringAerospace EngineeringCryosphere StudiesHeat TransferThermal AnalysisEquipment DesignGas InjectionPassive CoolingCryogenic CoolingCryogenic SafetyCryogenic System DesignCryogenic SystemsSpraySpray SystemsTank IntegrityVaporization
The literature for tank chilldown methods applicable to cryogenic tankage in the zero gravity environment of earth orbit is reviewed. One method is selected for demonstration in a ground based test. The method selected for investigation was the charge-hold-vent method which uses repeated injection of liquid slugs, followed by a hold to allow complete vaporization of the liquid and a vent of the tank to space vacuum to cool tankage to the desired temperature. The test was conducted on a 175 cubic foot, 2219 aluminum walled tank weighing 329 pounds, which was previously outfitted with spray systems to test nonvented fill technologies. To minimize hardware changes, a simple control-by-pressure scheme was implemented to control injected liquid quantities. The tank cooled from 440 R sufficiently in six charge-hold-vent cycles to allow a complete nonvented fill of the test tank. Liquid hydrogen consumed in the process is estimated at 32 pounds.