Analytical Chemistry · 2008 · 18 citations · 38 references
PharmacyPharmaceutical AnalysisPharmacologyDrug DiscoveryMass Spectrometric AnalysisProteomicsBioanalytical Method ValidationEnzyme InhibitionMass SpectrometryMass Spectrometry Data AnalysisMaldi-tof Mass SpectrometryMass Spectrometric Drug AnalysisMass Spectrometric QuantificationMass Spectrometry CharacterizationMatrix-assisted Laser Desorption Ionization Time-of-flight Mass SpectrometryMatrix-assisted Laser Desorption/ionization Time-of-flight Mass SpectrometryProtease InhibitorsSignal-to-noise Reduction
In this report we explore the use of MALDI-FTICR mass spectrometry for the quantitative analysis of five HIV-1 protease inhibitors in cell lysates. 2,5-Dihydroxybenzoic acid (DHB) was used as the matrix. From a quantitative perspective, DHB is usually a poor matrix due to its poor shot-to-shot and poor spot-to-spot reproducibilities. We found that the quantitative precisions improved significantly when DMSO (dimethylsulfoxide) was added to the matrix solution. For lopinavir and ritonavir, currently the most frequently prescribed HIV-1 protease inhibitors, the signal-to-noise ratios improved significantly when potassium iodide was added to the matrix solution. The mean quantitative precisions, expressed as % relative standard deviation, were 6.4% for saquinavir, 7.3% for lopinavir, 8.5% for ritonavir, 11.1% for indinavir, and 7.2% for nelfinavir. The mean quantitative accuracies, expressed as % deviation, were 4.5% for saquinavir, 6.0% for lopinavir, 5.9% for ritonavir, 6.6% for indinavir, and 8.0% for nelfinavir. The concentrations measured for the individual quality control samples were all within 85-117% of the theoretical concentrations. The lower limits of quantification in cell lysates were 4 fmol/microL for saquinavir, 16 fmol/microL for lopinavir, 31 fmol/microL for ritonavir, and 100 fmol/microL for indinavir and nelfinavir. The mean mass accuracies for the protease inhibitors were 0.28 ppm using external calibration. Our results show that MALDI-FTICR mass spectrometry can be successfully used for precise, accurate, and selective quantitative analyses of HIV-1 protease inhibitors in cell lysates. In addition, the lower limits of quantification obtained allow clinical applications of the technique.
38
Desorption–ionization mass spectrometry on porous silicon
Jing Wei, Jillian M. Buriak, Gary Siuzdak · Nature · 1999 · 1.1K citations
Prestructured MALDI-MS Sample Supports
Martin Schuerenberg, Christine Luebbert, Holger Eickhoff et al. · Analytical Chemistry · 2000 · 325 citations
A Method for the Analysis of Low-Mass Molecules by MALDI-TOF Mass Spectrometry
Zhong Guo, Qing‐Chun Zhang, Hanfa Zou et al. · Analytical Chemistry · 2002 · 195 citations