Journal of Cataract & Refractive Surgery · 2002 · 30 citations · 16 references
Health ProfessionsOphthalmologySurgeryOcular DiseaseOcular ImagingOphthalmic SurgeryEye ExaminationGlaucomaGlaucoma SurgeryIntraocular Pressure MeasurementOcular UltrasonographyRetinal ExaminationAnterior Segment Ultrasound BiomicroscopyGlaucoma After Cataract SurgeryIntraocular Pressure Control After SurgeryIntraocular Pressure ManagementIntraocular Pressure ReductionPeriocular Tissue ChangesSurgical Outcomes In GlaucomaTissue Morphology Changes
PURPOSE: To show tissue changes using ultrasound biomicroscopy (UBM) in eyes with controlled intraocular pressure (IOP) after viscocanalostomy. SETTING: Consultores Oftalmológicos, Fundación Oftalmológica Argentina Jorge Malbran and Hospital Santa Lucía, Buenos Aires, Argentina. METHODS: This retrospective noncomparative case series comprised 23 eyes of 19 patients with uncontrolled open-angle glaucoma who had viscocanalostomy and UBM and a mean follow-up of 20 months +/- 5.9 (SD) (range 12 to 30 months). The UBM measurements were taken a mean of 6.8 +/- 5.9 months (range 3 to 14 months) after the viscocanalostomy. In 7 eyes, UBM was again performed a mean of 7.8 +/- 4.6 months (range 7 to 9 months) after the first study. All patients had preoperative and postoperative IOP measurements. RESULTS: The mean IOP at last examination was 13.3 +/- 2 mm Hg (range 8 to 17 mm Hg). One eye had evidence of a subconjunctival bleb. All eyes had a nonreflective scleral chamber and posterior to it, a hyporeflective zone. In 7 eyes in which 2 UBMs were performed, the scleral chamber was unchanged 7 to 9 months after the first study. CONCLUSIONS: The presence of a scleral chamber and absence of a subconjunctival filtering bleb are the usual UBM findings in eyes with adequate control of IOP several months after viscocanalostomy. These findings suggest that viscocanalostomy is successful when a continuous aqueous flow through the trabeculo-Descemet's membrane is present, maintaining a scleral chamber.
16
Deep sclerectomy: results with and without collagen implant
E Hernández Sánchez, CorinneC. Schnyder, Michel Sickenberg et al. · International Ophthalmology · 1997 · 190 citations
Medicine, Ophthalmology, Surgery +4
Deep sclerectomy with collagen implant: medium term results
M. E. Karlen, E Hernández Sánchez, C Schnyder et al. · British Journal of Ophthalmology · 1999 · 183 citations · Full text
Medicine, Ophthalmology, Surgery +15
An ultrasound biomicroscopic study of eyes after deep sclerectomy with collagen implant
Auguste G.-Y. Chiou, André Mermoud, Jerald P. Underdahl et al. · Ophthalmology · 1998 · 144 citations · Full text
Medicine, Ophthalmology, Surgery +14