Aluminum/Cryolite Reference Electrodes for Use in Cryolite‐Based Melts

John W. Burgman, James A. Leistra, Paul J. Sides

Journal of The Electrochemical Society · 1986 · 19 citations · 0 references

Concepts

Abstract

Two reference electrodes for use in cryolite‐based melts have been developed and tested. In the "wetted molybdenum hook" design, aluminum wets a well‐defined length of molybdenum wire in cryolite saturated with alumina. The hook design allows the immersion, in the molten aluminum, of a seal between the molybdenum lead and a protective sheath. In the "densified bath inverted" design, aluminum floats above a cryolite mixture containing 30% . The reference electrodes were compared to each other and to a molybdenum wire on which aluminum had been cathodically deposited. The wetted molybdenum hook electrodes, preferred by the authors, were found to be stable with respect to each other within 5 mV for the 8h testing period.