American Journal of Respiratory and Critical Care Medicine · 2011 · 226 citations · 21 references
MedicineInternal MedicineFunctional AssessmentPulmonary Function TestingSleep MedicineContinuous Positive Airway PressurePositive Airway Pressure TherapySleep Apnea CareSleep DisturbanceSleep-disordered BreathingSleep-related Breathing DisordersAdherenceFunctional Outcome EvaluationFunctional Outcome MeasurementObstructive Sleep Apnea TherapyObstructive Sleep Apnea TreatmentPositive Airway Pressure AdherenceSleep Apnea DiagnosisSleep Apnea Outcome Measurement
RATIONALE: Home portable monitor testing is increasingly being used to diagnose patients with obstructive sleep apnea (OSA) and to initiate them on continuous positive airway pressure (CPAP) treatment. OBJECTIVES: To compare functional outcome and treatment adherence in patients who receive ambulatory versus in-laboratory testing for OSA. METHODS: Veterans with suspected OSA were randomized to either home testing or standard in-laboratory testing. Home testing consisted of a type 3 portable monitor recording followed by at least three nights using an automatically adjusting positive airway pressure apparatus. Participants diagnosed with OSA were treated with CPAP for 3 months. MEASUREMENTS AND MAIN RESULTS: We measured the change in Functional Outcomes of Sleep Questionnaire score, with an a priori noninferiority delta of -1, and the mean daily hours of objectively measured CPAP adherence, with an a priori noninferiority delta of -0.75 hour/day. Of the 296 subjects enrolled, 260 (88%) were diagnosed with OSA, and 213 (75%) were initiated on CPAP. Mean ± SD functional outcome score improved 1.74 ± 2.81 in the home group (P < 0.001) and 1.85 ± 2.46 in the in-laboratory group (P < 0.0001). The lower bound of the one-sided 95% noninferiority confidence interval was -0.54. Mean ± SD hours of daily CPAP adherence were 3.5 ± 2.5 hours/day in the home group and 2.9 ± 2.3 hours/day in the in-laboratory group (P = 0.08). The lower bound of the one-sided 95% noninferiority confidence interval was 0.03. CONCLUSIONS: Functional outcome and treatment adherence in patients evaluated according to a home testing algorithm is not clinically inferior to that in patients receiving standard in-laboratory polysomnography.
21
Lenore Sawyer Radloff · Applied Psychological Measurement · 1977 · 53.3K citations · Full text
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Murray W. Johns · SLEEP · 1991 · 17.2K citations · Full text
Medicine, Neurology, Psychometrics +16
A 12-Item Short-Form Health Survey
John E. Ware, Mark Kosinski, Susan Keller · Medical Care · 1996 · 17.1K citations