Journal of Fire Sciences · 1984 · 23 citations · 2 references
PharmacyEnvironmental SciencesToxicologyAnalytical ToxicologyEnvironmental ToxicologyIndustrial ToxicologyChemical SafetyInhalation ToxicologyCombustion Product ToxicityCombustion ToxicityNon-toxic MaterialsSmoke Hazard AssessmentSmoke Toxicity AssessmentSmoke Toxicity TestingToxic Smoke Exposure
Small-scale smoke toxicity tests were performed on polyvinylchloride-based electrical nonmetallic tubing (PVC/ENT) using the National Bureau of Stan dards (NBS) protocol for nonflaming combustion. An LC 50 of 28.5 mg/L (± 9.25) was determined, placing PVC/ENT smoke in a toxicity category comparable to smoke from wood.
2
Noxious Gases and the Principles of Respiration Influencing Their Action.
JAMA · 1928 · 84 citations