Proceedings of the Institution of Mechanical Engineers · 1956 · 36 citations · 6 references
EngineeringMechanical EngineeringFluid DynamicsHeat TransferTransport PhenomenaHeat FlowHeat Transfer AnalysisHeat Transfer In FluidsHeat Transfer ModelingPipe FlowDivergenceEntryHeat Transfer In PipesReynolds Number
The effect of an abrupt convergence, diameter ratio 2/1, on the local heat-transfer coefficient for water flowing in a straight pipe has been determined for Reynolds numbers from 800 to 100,000 in the smaller pipe, which had an internal diameter of 1 inch. The pipe was heated by the longitudinal passage of a heavy direct current through the wall. The variation in local coefficient, which was comparatively small, is presented and discussed; it does not differ greatly from the variation found in the entry regions of pipes under more normal entry conditions. The effect of an abrupt divergence, diameter ratio 1/2, has also been determined for Reynolds numbers from 3,700 to 45,000 in the larger (2-inch) pipe. The variation in local coefficient was considerable.
6
Heat Transfer and Pressure Drop of Liquids in Tubes
E.N. Sieder, G. E. Tate · Industrial & Engineering Chemistry · 1936 · 2.2K citations
Properties of ordinary water-substance
R.H. Oppermann · Journal of the Franklin Institute · 1940 · 833 citations