Concepedia

Publication | Closed Access

Binaural–bimodal hearing: Concomitant use of a unilateral cochlear implant and a contralateral hearing aid

69

Citations

14

References

2005

Year

Abstract

At the first testing session, the mean score in background noise was 34.9% with CI alone (range 0-90%) and 41.1% with both devices (range 0-100%). Seven patients could recognize sentences in noise with CI alone, and four of them showed further improvement with added amplification. At the second session, at which all subjects could recognize sentences in noise with the CI alone, seven showed further improvement with added amplification. The mean score was 60.6% with CI alone (range 10-99%) and 75.5% with both devices (range 52-100%).