In order to determine the Counter-Current Flow Limitation (CCFL) in hot legs of PWRS, CCFL characteristics of air-water and saturated steam-water flow were experimentally investigated in a modeled flow path of a horizontal tube connected to an inclined riser. The ranges of dimensions of experimental tubes were as follows: diameter D 0.026–0.076 m, length of horizontal tube H 0.01–0.4 m, length of inclined riser I 0.038–0.6 m and inclination angle of inclined riser θ 40° or 45°. Wallis-type correlation (J g *1/2+mJ i *1/2=C) was applicable to the data during a steady separated flow. An analysis based on envelope theory showed that the constant C should be a function of H/D and I. A function of C with those parameters was empirically determined by using data obtained in this study. The developed function correlated well with the results of Richter et al. (D = 0.203 m, H = 1.26 m, I = 0.5 m and θ = 45°). The constant m in the Wallis-type correlation was almost constant 0.75. The problems were discussed, which should be made clear to apply the correlation obtained in this study to an actual PWR hot leg.