Prone Positioning for Testing Shoulder Internal and External Rotation on the Cybex II<sup>®</sup>Isokinetic Dynamometer

Jeffrey E. Falkel, Timothy C. Murphy, Thomas F. Murray

Journal of Orthopaedic and Sports Physical Therapy · 1987 · 21 citations · 1 references

DOIFull text

Open access

Concepts

Abstract

This study was undertaken to test the feasibility of using a prone test position on the Upper Body Exercise Table while performing shoulder internal and external rotation in swimmers using a Cybex II® Isokinetic Dynamometer. Thirty-nine swimmers, 20 males and 19 females, were tested for internal and external rotation of the shoulder in supine position and, on a separate occasion, in the prone position at speeds of 120, 180, and at 240°/sec. In addition, they performed a 50-contraction endurance trial at 240° in both positions. The results of the study showed that with the exception of 120°/sec for the external rotators, the prone position produced significantly greater (p < 0.05) torque values than while supine. It is suggested that while testing swimmers, the prone position be used to obtain the highest strength and endurance values.

References

1