PubMed · 1974 · 304 citations · 8 references
MedicineAnesthesiologySurgeryAnesthesiaPulmonologyResuscitationAirway AssessmentAirway ManagementAirway SupportRespiratory ComplicationsThoracic SurgeryBronchoscopyBronchoscopy-induced ComplicationsRespiratory Depression MonitoringThoracic BiopsyTransbronchial Biopsy
A survey of the complications of fiberoptic bronchoscopy in 24,521 procedures revealed a low incidence of major complications and mortalities, 0.08 per cent and 0.01 per cent, respectively. Most complications encountered appeared to have been readily preventable. Examination of the patient should always be performed to ensure that he will be in optimal condition before the procedure and that appropriate monitoring will be carried out when indicated. Equipment for cardiovascular and respiratory resuscitation should always be readily available and were lifesaving in several patients in this study. The dosages of both premedication and topical anesthesia must be limited to avoid respiratory depression or systemic toxicity. Of a number of factors to consider in avoiding hypoxemia, maintenance of a patent airway, supplying adequate inspired oxygen, and avoiding oversedation are of utmost importance. Finally, it should be recognized that ancillary procedures, such as blind brushing and transbronchial biopsy, ca...
8
Flexible Fiberoptic Bronchoscope
Joseph F. Smiddy · Annals of Internal Medicine · 1971 · 39 citations