The Biomechanics of Locked Plating for Repairing Proximal Humerus Fractures With or Without Medial Cortical Support

121

Citations

63

References

2010

Year

Abstract

Anatomic reduction with the medial cortical contact was the stiffest construct after a simulated two-part fracture. This study affirms the concept of medial cortical support by fixing proximal humeral fractures in varus, if absolutely necessary. This may be preferable to fixing the fracture in anatomic alignment when there is a medial fracture gap.