Publication | Open Access
Preoperative Measurement of Cartilage Defects by MRI Underestimates Lesion Size
93
Citations
11
References
2011
Year
Our study compared the size of cartilage defects measured by preoperative MRI with surgical measurements after debridement. On average, the final total defect area per knee was 65% larger than estimated preoperatively by MRI. Individual defects were larger than predicted by 47% to 377%, depending on defect location.