Physiological Measurement · 2009 · 85 citations · 23 references
EngineeringCardiologyPhysiologyBioinstrumentationElectrophysiologyPhysiological Systems ModelingBiopotential MeasurementBlood Pressure Signal AnalysisCardiovascular AssessmentCardiovascular MonitoringElectrocardiographyMedical InstrumentationBlood PressureBlood Pressure EstimationBlood Pressure MeasurementCuffless Blood Pressure MeasurementDry ElectrodesNoninvasive Blood Pressure MeasurementSystolic Blood PressureSystolic Blood Pressure Estimation
In this study, we developed a novel technique for estimating non-constrained and cuffless blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram (BCG). The BCG was non-invasively measured using a common electronic weighing scale when a subject was standing on it. The ECG was measured using three different methods: on the chest using Ag/AgCl electrodes, on the hands using dry electrodes and on the feet also using dry electrodes. For a BP correlated parameter, a time interval parameter, which was defined as the time difference between the ECG R-peak and BCG J-peak, was employed for evaluating and estimating beat-to-beat BP. Under a BP varying experiment with a Valsalva manoeuvre, the R-J intervals were extracted at every beat cycle and a systolic blood pressure (SBP) estimation equation was established using linear regression analysis for each subject. In the case of feet delivered ECG (F-ECG), an ensemble average technique synchronized at the BCG J-peak point was applied to extract the ECG signal from the feet. The performance of the proposed method was evaluated using Finapres, a non-invasive blood pressure measurement system, as a reference BP signal, and a scatter plot was used to find the regression line between the reference values and estimated BPs. A moving-window averaging technique was applied to remove the high-frequency noise in the R-J intervals and was applied to enhance the accuracy of the SBP estimation. For all individuals, the estimated SBP was similar to the measured SBP with a reliable correlation, which makes the proposed method suitable for use in a home healthcare system to monitor blood pressure on a weighing scale at the same time as measuring weight.
23
A Real-Time QRS Detection Algorithm
Jiapu Pan, W.J. Tompkins · IEEE Transactions on Biomedical Engineering · 1985 · 7.7K citations
Pulse Transit Time as an Indicator of Arterial Blood Pressure
L. A. Geddes, M. H. Voelz, Charles F. Babbs et al. · Psychophysiology · 1981 · 290 citations
Robust ballistocardiogram acquisition for home monitoring
Omer T. Inan, Mozziyar Etemadi, Richard M. Wiard et al. · Physiological Measurement · 2009 · 230 citations
Engineering, Cardiology, Physiology +10