Catheterization and Cardiovascular Diagnosis · 1985 · 18 citations · 2 references
MedicineCardiologyClinical CardiologyInterventional CardiologyBalloon AngioplastyCoronary AngioplastyCoronary Artery DiseaseMyocardial Infarction ComplicationsPercutaneous Coronary InterventionPulmonary EmbolismAngioplasty ComplicationsCoronary Balloon Angioplasty
A patient undergoing percutaneous transluminal angioplasty of a critical proximal stenosis of his anterior descending coronary artery died as a result of coronary air embolism from a defective dilatation catheter. The probable mechanism responsible for this lethal complication is discussed. Simple precautions are described that will prevent its future occurrence.
2
Nonoperative Dilatation of Coronary-Artery Stenosis
A Grüntzig, A Senning, W Siegenthaler · New England Journal of Medicine · 1979 · 2.4K citations
Medicine, Cardiology, Surgery +13