Journal of Children s Orthopaedics · 2015 · 27 citations · 18 references
Our findings of contextually high metal ion concentrations in intraoperative and early postoperative samples provide further empirical support of a 'putting-in' phenomenon of metal ion release following instrumented spinal fusion. This challenges existing beliefs that metal ion release occurs during an intermediate 'wearing-in' phase. We recommend thorough irrigation of the operative site prior to wound closure to dilute and remove intraoperative metal ion debris. Possibilities of filtering trace metal ions from cell saver content may be considered.
18
Spinal Implant Debris-Induced Osteolysis
Nadim J. Hallab, Brian W. Cunningham, Joshua J. Jacobs · Spine · 2003 · 198 citations