Review of Scientific Instruments · 1997 · 14 citations · 10 references
EngineeringMaterials SciencePhysicsHeat TransferMetrologySensorsFlow SensorsTemperature MeasurementTemperature SensorsThermal SensorsTurbulenceTurbulent FlowCryogenic DetectorsCryogenic Temperature MeasurementCryogenic Temperature SensorsCryogenic ThermometryHigh-reynolds-number FlowSpatial Resolution MeasurementTurbulence MeasurementTurbulent Flow Measurement
Micronic-size thermometers (1.5×1.5×0.5 μm3) designed for local measurements in turbulent gaseous helium in the range of 4–80 K, have been developed and tested. Their very short time response (⩽1 μs) and micronic spatial resolution allow to perform measurements down to the Kolmogorov dissipative length scale, for high Reynolds or Rayleigh numbers flows. These thermometers, designed to be nonperturbative in the flow, are based on Au–Ge thin films deposited by sputtering process on drawn glass fibers. Their relative sensitivities σ=|(T/R)(dR/dT)| are ranging from 0.15 to 0.9, and are nearly constant on the whole temperature range.
10
Frequency power spectrum of temperature fluctuations in free convection
Xiao-Zhong Wu, Leo P. Kadanoff, Albert Libchaber et al. · Physical Review Letters · 1990 · 197 citations
Free convection in low-temperature gaseous helium
D. C. Threlfall · Journal of Fluid Mechanics · 1975 · 152 citations
Metal-Insulator Transition in Disordered Germanium-Gold Alloys
Brian W. Dodson, W. L. McMillan, J. M. Mochel et al. · Physical Review Letters · 1981 · 147 citations