Physical review. A, General physics · 1988 · 39 citations · 22 references
EngineeringPhysicsRadiation DetectionRadiation MeasurementRadiation PhysicsCharged Particle DetectionCounting StatisticsEnergy ResolutionIonization ProcessesParticle DetectorsRadiation DetectorsCharge CollectionIonization Chamber DetectorsIonization DetectionPoisson Counting Statistics
There is a fundamental limit to the resolution that can be achieved in liquid-argon and liquid-xenon ionization detectors due to statistical fluctuations in the rate of charge collection along the track of a primary particle. The limit is typically much larger than the resolution expected from Poisson statistics. We present resolution data in both argon and xenon, a model to describe the data, and a discussion of how the model parameters can be manipulated in order to achieve even greater resolution.
22
Lars Onsager · Physical Review · 1938 · 1.9K citations
Molière's Theory of Multiple Scattering
Hans A. Bethe · Physical Review · 1953 · 874 citations
Charge Transport in Solid and Liquid Ar, Kr, and Xe
L. S. Miller, S. H. Howe, W. E. Spear · Physical Review · 1968 · 350 citations