American Journal of Roentgenology · 2010 · 103 citations · 21 references
MedicineRadiologySurgeryCardiothoracic SurgeryDiagnostic ImagingDiagnostic RadiologyAortic StenosisAortic Valve DiseaseCardiac ImagingCardiac Valve SurgeryCardiothoracic ImagingCardiovascular ImagingAortic Stenosis AssessmentAortic Valve Disease ImagingAortic Valve EvaluationAortic Valve ImagingBicuspid Aortic Valve StenosisEchocardiographic InterpretationPositive Predictive ValueValve Calcification Assessment
OBJECTIVE: This study was conducted to assess the diagnostic value of cardiac CT for the evaluation of patients with bicuspid aortic valve disease. MATERIALS AND METHODS: Fifty consecutive patients with aortic stenosis who underwent surgical valve repair between September 2005 and November 2006 were examined by ECG-gated CT and echocardiography. A 64-MDCT scanner was used. The image findings regarding the number of leaflets (bicuspid or tricuspid) were compared against the intraoperative findings and were statistically analyzed by one-way univariate analysis of variance. The aortic valve area (AVA) was also measured by CT and echocardiography, and the measured values were statistically compared by use of the paired Student's t test. RESULTS: Seventeen patients had a bicuspid aortic valve, and 33 had a tricuspid aortic valve. In 10 of the 50 patients, echocardiography was unable to depict the type of aortic valve because of extensive calcification. The sensitivity, specificity, positive predictive value, and negative predictive value for the detection of a bicuspid aortic valve were 76.5%, 60.6%, 68.4%, and 95.2%, respectively, for echocardiography and 94.1%, 100%, 100%, and 97.1%, respectively, for CT. The CT findings were not significantly different from the intraoperative findings (p = 0.99), but the echocardiographic findings were (p < 0.05). The AVA measurements obtained by CT and echocardiography were 0.940 ± 0.44 cm(2) and 0.659 ± 0.234 cm(2), respectively, showing a significant difference (p < 0.05). CONCLUSION: ECG-gated cardiac CT is useful for the accurate morphologic assessment of bicuspid aortic stenosis, especially in patients with severe valve calcification.
21
Atherosclerotic Disease of the Aortic Arch and the Risk of Ischemic Stroke
Pierre Amarenco, Ariel Cohen, Christophe Tzourio et al. · New England Journal of Medicine · 1994 · 1K citations
Medicine, Cardiology, Neurology +15
Clinical and Pathophysiological Implications of a Bicuspid Aortic Valve
Paul W.M. Fedak, Subodh Verma, Tirone E. David et al. · Circulation · 2002 · 789 citations · Full text
Medicine, Cardiology, Surgery +14
Surgical treatment of the dilated ascending aorta: when and how?
David Spielvogel, Steven Lansman, Jock N. McCullough et al. · The Annals of Thoracic Surgery · 1999 · 217 citations
Medicine, Cardiology, Surgery +13