High-Reynolds-Number Cryogenic Wind Tunnel

Michael J. Goodyer, R. A. Kilgore

AIAA Journal · 1973 · 49 citations · 1 references

Concepts

Abstract

Theoretical considerations indicate that cooling the wind-tunnel test gas to cryogenic temperatures will provide a large increase in test Reynolds number with no increase in dynamic pressure while reducing the tunnel drive-power requirements. Studies have been made to determine the expected variations of Reynolds number and other parameters over wide ranges of Mach number, pressure, and temperature with due regard to avoiding liquefaction and adverse real-gas effects. Practical operational procedures have been developed in a low-speed prototype cryogenic wind tunnel. Aerodynamic experiments in the facility have demonstrated the theoretically predicted variations in Reynolds number and drive power. Force and moment measurements on a wing model mounted on a water-jacketed strain-gage sting balance have demonstrated the feasibility of operation of such balances in a cryogenic environment.

References

1