Journal of Computer Assisted Tomography · 1995 · 27 citations · 0 references
Natural SciencesBiophysicsRadiologyDiagnostic ImagingDiagnostic RadiologyMedical PhysicsMagnetic Resonance Contrast MechanismsMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMagnetic Resonance Pulse SequencesMagnetic Resonance Signal FormationRelaxation MechanismsExponential DecayGradient Echo SequencesMagnetic Field StrengthT2 ContrastT2 RelaxationT2* ImagingTransverse Relaxation TimeVertebral Bodies
The study aims to quantify how magnetic field strength influences T2* and T2susceptibility relaxation rates in vertebral bone marrow and to assess the impact of in‑phase/out‑of‑phase effects in gradient‑echo MRI across different echo times. The authors performed spine MRI at 1.5, 1.0, and 0.2 T using a 2D‑FLASH gradient‑echo sequence with variable echo times, measured vertebral body signal intensities, and derived T2* decay curves for each field strength. T2* decay in vertebral bone marrow follows an exponential curve modulated by a cosine whose period scales with B0; T2* values increase from 9.7 ms at 1.5 T to 53 ms at 0.2 T, while true T2 remains ~62 ms, indicating that at low field strengths susceptibility effects diminish and T2* approaches true T2.
Objective The goal of this study was twofold: first, to quantify the influence of magnetic field strength (B0) on T2* and T2susceptibility relaxation rates in vertebral bone marrow; and second, to determine the significance of in-phase/out-of-phase phenomena in GE MRI as a function of TEs at different B0 values. Materials and Methods Magnetic resonance imaging of the spine was performed at 1.5, 1.0, and 0.2 T using a GE sequence (2D-FLASH) with variable TE. Vertebral body signal intensities were measured and plotted against TE values. These curves were used to calculate T2* decay of bone marrow at different B0, values. Results At all field strengths, we observed exponential signal decay, modulated by a cosine function, the periodicity of which was proportional to B0. The T2* values of vertebral bodies were 9.7 ± 1.8 ms at 1.5 T, 17.2 ± 2.4 ms at 1.0 T, and 53 ± 5 ms at 0.2 T. True T2 relaxation time (independent of field strength) was 62 ± 4 ms. The T2susceptibility was 11.7 ms at 1.5 T. 24.8 ms at 1.0 T, and 585 ms at 0.2 T. Conclusion We conclude that at low B0, susceptibility effects become less important and T2* approaches true T2 relaxation.