IEEE Transactions on Magnetics · 2015 · 12 citations · 10 references
Natural SciencesMaterials EngineeringMaterials ScienceCondensed Matter PhysicsMagnetic MaterialsNanomaterialsMagnetic CharacterizationMagnetic NanomaterialsMagnetic SensorsMagnetization ProcessesHarmonic ResponseHarmonicsMagnetic NanoparticlesNanoparticlesQuantum InterferenceSaturationSaturation RegionSuperconducting Quantum Interference Device Magnetometry
We have developed a method to improve the detection sensitivity for the magnetization M of magnetic nanoparticles (MNPs) using a high T <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> superconducting quantum interference device magnetometer. The M response of MNP to an applied magnetic field H(M-H characteristics) can be divided into a linear region and a saturation region, which are separated at a transition point H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">k</sub> . When applying an excitation ac magnetic field (H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ac</sub> ) and an additional dc bias field H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dc</sub> = H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">k</sub> , the second harmonic of M reaches a maximum due to the nonlinearity of its M-H characteristics. This harmonic is stronger than any other harmonics, including a third harmonic. The advantage of using the second harmonic response is that the response can be measured even in a small field H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ac</sub> . The M response of MNP was systematically analyzed and experimentally demonstrated. For conventional detection using a third harmonic, the amplitude of the H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ac</sub> must be larger than the threshold level, which is almost the same as H <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">k</sub> . Detection methods using a second harmonic can be applied to magnetic particle imaging. We finally demonstrate the construction of a 1-D image of two separated bottle-shaped MNP samples using the method with a lock-in amplifier.
10
An x-space magnetic particle imaging scanner
Patrick Goodwill, Kuan Lu, Bo Zheng et al. · Review of Scientific Instruments · 2012 · 129 citations · Full text