Note: Construction of x-ray scattering and x-ray absorption fine structure beamline at the Pohang Light Source

Ik-Jae Lee, Chung-Jong Yu, Young-Duck Yun, Chae-Soon Lee, In Deuk Seo, Hyo-Yun Kim, Woul-Woo Lee, Keun Hwa Chae

Review of Scientific Instruments · 2010 · 13 citations · 4 references

Concepts

Abstract

A new hard x-ray beamline, 10B KIST-PAL beamline (BL10B), has been designed and constructed at the Pohang Light Source (PLS) in Korea. The beamline, operated by Pohang Accelerator Laboratory-Korean Institute of Science and Technology consortium, is dedicated to x-ray scattering (XRS) and x-ray absorption fine structure (XAFS) experiments. X rays with photon energies from 4.0 to 16.0 keV are delivered to the experimental station passing a collimating mirror, a fixed-exit double-crystal Si(111) monochromator, and a toroidal mirror. Basic experimental equipment for XAFS measurement, a high resolution diffractometry, an image plate detector system, and a hot stage have been prepared for the station. From our initial commissioning and performance testing of the beamline, it is observed that BL10B beamline can perform XRS and XAFS measurements successfully.

References

4