Medical Physics · 1987 · 51 citations · 0 references
MedicineRadiologyRadiation DosimetryRadiation PhysicsRadiation TransportAbsorbed DoseExternal Beam DosimetryPhantom DosimetryPhoton AttenuationPhoton DosimetryRadiation Dose MeasurementDose Distribution CalculationsDose Perturbation AnalysisExternal Beam Dose DistributionHigh-energy Photon Beam DosimetryParticle Beam DosimetryPhoton Dose CalculationPhoton Dose DistributionSolid Phantoms
A model based on an approximation called the partial fluence approximation is presented for the calculation of dose distributions in the vicinity of medium interfaces in photon beams. The predictions of the model are compared with dose distributions measured in layered phantoms consisting of aluminum and polystyrene, for photon beams ranging in energy from 60Co to 24 MV.