Journal of Aerosol Medicine and Pulmonary Drug Delivery · 2010 · 37 citations · 27 references
Model predictions agree well with measurements of total and pulmonary lung deposition for particles of 10 nm to 10 μm, with earlier models incorporating moving boundaries and aerosol dynamics, and with the reported regional lung deposition of inhaled dry powder insulin. To simulate medical inhalation, the model was run with inhalation times from 2-6 sec and breath hold from 0-10 sec. A high and relatively invariant pulmonary deposition fraction between 70 and 95% was predicted for a broad nanoparticle size range (50-200 nm) for inhalation cycles with breathing rate between 500 and 2000 cm(3) sec(-1) and breath hold of 5-10 sec. Thus, nanoparticles may be able to deliver consistent lung doses, over modest breath hold periods, even with intrapatient variability in breathing rate. A linearized nomogram was provided as a heuristic for design of nanoparticle drug matrices to target the pulmonary lung.