IEEE Transactions on Biomedical Engineering · 1998 · 44 citations · 7 references
EngineeringBiomedical EngineeringCardiologyBioinstrumentationBiomedical Signal ProcessingElectrophysiologyBiomedical Signal CompressionCardiac Signal ProcessingData CompressionDigital Signal ProcessingElectrocardiogram AnalysisElectrocardiographyCompressionCompression TechniquesEcg Signal CompressionEcg Signal ReconstructionElectrocardiogram CompressionMultirate SamplingMultirate Signal ProcessingSignal Quality Assessment
An electrocardiogram (ECG) compression algorithm based on a combination of the Karhunen-Loeve transform (KLT) and multirate sampling is introduced. The use of multirate sampling reduces KLT computational times to those reported for wavelet-packet-based compression techniques. A beat-by-beat quality controlled compression criterion is shown to be necessary to ensure clinically adequate reconstruction of each beat. The resulting quality controlled algorithm efficiently achieves compression rates of approximately 30-40:1 for the MIT-BIH database.
7
The MIT-BIH Arrhythmia Database on CD-ROM and software for use with it
G.B. Moody, Roger G. Mark · 2002 · 403 citations