Annals of the ICRP · 2010 · 337 citations · 123 references
MedicineOrthopaedic SurgeryRadiologyInterventional RadiologyRadiation ProtectionRadiation SafetyFluoroscopy-guided ProceduresOccupational Radiation ProtectionOccupational Radiation SafetyPatient Radiation ProtectionPatient Radiation SafetyRadiation Protection PrinciplesInterventional Radiology Radiation ProtectionMedical Radiation RiskProcedure-related Radiation SafetyRadiation Protection In RadiologyRadiation Safety In FluoroscopyRadiation Shielding For PatientsRadiological Protection TrainingTissue Reactions
Fluoroscopy increasingly used outside imaging departments, yet radiological protection training is lacking, exposing workers and patients to high skin doses that can exceed Gy and cause tissue reactions. The paper aims to provide a concise overview of ionising radiation health effects and protection principles for fluoroscopy outside imaging departments. The authors outline general protection measures in Section 3 and detail specialty‑specific protocols in Section 4 for vascular, urological, orthopaedic, obstetric, gynaecological, gastroenterological, hepatobiliary, anaesthetic, and pain‑management procedures. The report presents radiation dose levels and dose‑management strategies for patients and workers across each specialty.
An increasing number of medical specialists are using fluoroscopy outside imaging departments, but there has been general neglect of radiological protection coverage of fluoroscopy machines used outside imaging departments. Lack of radiological protection training of those working with fluoroscopy outside imaging departments can increase the radiation risk to workers and patients. Procedures such as endovascular aneurysm repair, renal angioplasty, iliac angioplasty, ureteric stent placement, therapeutic endoscopic retrograde cholangio-pancreatography,and bile duct stenting and drainage have the potential to impart skin doses exceeding Gy. Although tissue reactions among patients and workers from fluoroscopy procedures have, to date, only been reported in interventional radiology and cardiology,the level of fluoroscopy use outside imaging departments creates potential for such injuries.A brief account of the health effects of ionising radiation and protection principles is presented in Section 2. Section 3 deals with general aspects of the protection of workers and patients that are common to all, whereas specific aspects are covered in Section 4 for vascular surgery, urology, orthopaedic surgery, obstetrics and gynaecology,gastroenterology and hepatobiliary system, and anaesthetics and pain management.Although sentinel lymph node biopsy involves the use of radio-isotopic methods rather than fluoroscopy, performance of this procedure in operating theatres is covered in this report as it is unlikely that this topic will be addressed in another ICRP publication in coming years. Information on radiation dose levels to patients and workers, and dose management is presented for each speciality.
123
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
Reza Fazel, Harlan M. Krumholz, Yongfei Wang et al. · New England Journal of Medicine · 2009 · 1.3K citations · Full text
Radiation Exposure to the Spine Surgeon During Fluoroscopically Assisted Pedicle Screw Insertion
Y. Raja Rampersaud, Kevin T. Foley, Alfred C. Shen et al. · Spine · 2000 · 566 citations
G. Chodick, Nural Bekiroğlu, Michael Hauptmann et al. · American Journal of Epidemiology · 2008 · 407 citations · Full text
Space Radiation and Cataracts in Astronauts
Francis A. Cucinotta, F. K. Manuel, Jeffrey A. Jones et al. · Radiation Research · 2001 · 391 citations