Validation of CFD Simulations of Cerebral Aneurysms With Implication of Geometric Variations
155
Citations
42
References
2006
Year
CFD simulation results can closely match experimental measurements as long as both are performed on the same model geometry. Small geometric variations on the aneurysm model can significantly alter the flow-field and key hemodynamic parameters. Since medical images are subjected to geometric uncertainties, image-based patient-specific CFD results must be carefully scrutinized before providing clinical feedback.